Planning application

3.3 Information on insulation tests, protection class and degree of protection

3.3
Information on insulation tests, protection class and degree of
protection
Test voltages
Insulation strength is demonstrated in the type test with the following test voltages in
accordance with IEC 61131-2:
Circuits with a nominal voltage of U
circuits or ground
< 50 V
56
to other
Test voltage
e
500 VDC
Operating Instructions, 12/2007, A5E01003940-01