Siemens SIMATIC HMI Operating Instructions Manual page 163

Hmi device mobile panel 277f iwlan
Hide thumbs Also See for SIMATIC HMI:
Table of Contents

Advertisement

NOTICE
Settings under "Project File" and "Path"
Do not change the setting in the "Project File" and "Path:" boxes. The project may not open
at the next start of the HMI device if changes are made here.
Procedure for setting the delay time
1. Select the desired delay time in seconds from the "Wait [sec]:" selection box.
2. Confirm your entries.
Result
The delay time for the HMI device is now set.
Mobile Panel 277F IWLAN
Operating Instructions, 12/2007, A5E01003940-01
Directory where the project file is saved
Directory where the compressed source file of your project is saved
The external memory card or the network connection can be defined as the storage location.
During the next backup process, the project's source file is stored in the specified location.
Memory location and start file of the HMI device for the executable project file
Delay time selection box
With the value "0", the project starts immediately. It is now no longer possible to call the
Loader after switching on the HMI device. If you still do need to access the Loader an
operating element must be configured to close the project.
The dialog closes.
Configuring the operating system
6.8 Setting the delay time
163