Final Operations - Smeg CSA19ID-6 Owner's Manual

Smeg microwave oven owner's manual
Table of Contents

Advertisement

Instructions for the installer
3.4 Regulation of primary air
Referred to distance "X" in mm.
Burner
Auxiliary
Semi rapid
Rapid
Wok
Fish burner (*)
(*) Models CSA19 / CSA196

4. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance
following, backwards, the instructions in paragraph "3.1 Raising of the
hob".
4.1 Adjustment of minimum for natural gas
Light the burner and take it to the minimum
Remove the gas tap knob and turn the
adjustment screw inside or at the side of the tap
shaft (depending on the model) until there is a
regular minimum flame. Replace the knob and
check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the
flame should not go out). Repeat the operation on
all the gas taps.
4.2 Adjustment of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the
screw inside or next to the gas tap pin (depending on the model).
Models CSA19 / CSA196 / CSA20
NG
1.00 kPa
3.0
3.0
3.0
4.0
4.0
.
LPG
2.75 kPa
2.5
2.0
2.0
2.5
4.0
13

Advertisement

Table of Contents
loading

Table of Contents