3.2 Adjustment for LPG
Loosen screw A and push air regulator B to
the bottom. With a 7 mm wrench, remove
nozzle C and replace it with the proper one
(follow the instructions on the reference
tables for the type of gas to be used). The
torque wrench setting of the nozzle must not
exceed 3 Nm. Adjust the air by sliding
regulator B until reaching distance "X"
shown in the table in paragraph "3.4
Regulation of primary air". Lock regulator B
by tightening screw A.
Burner
Nominal gas
consumption
(MJ/h)
Auxiliary
4.80
Semi rapid
5.80
Rapid
9.30
Wok
13.00
Fish burner (*)
9.20
(*) Models CSA19 / CSA196
3.3 Adjustment for natural gas
The hob has been tested for natural gas at a pressure of 1.0kPa. To
allow the unit to work with this type of gas, perform the same operations
described in paragraph "3.2 Adjustment for LPG", but choose the nozzles
and adjust the primary air for natural gas, as shown in the following table
and in paragraph "3.4 Regulation of primary air".
Burner
Nominal gas
consumption
(MJ/h)
Auxiliary
5.30
Semi rapid
6.60
Rapid
9.00
Wok
12.50
Fish burner (*)
10.20
(*) Models CSA19 / CSA196
12
Instructions for the installer
Model CSA19
LPG – 2.75 kPa
Turn-down gas
Injector
consumption
(mm)
(MJ/h)
1.5
0.60
1.5
0.67
3.2
0.85
5.4
1.00
3.2
0.85
Model CSA19
NG – 1.00 kPa
Turn-down gas
Injector
consumption
(mm)
(MJ/h)
1.4
1.04
1.4
1.15
2.4
1.35
4.3
1.65
3.2
1.45
Models CSA196 / CSA20
LPG – 2.75 kPa
Nominal gas
Turn-down gas
consumption
consumption
(MJ/h)
(MJ/h)
5.30
1.5
6.60
1.5
9.00
3.2
15.00
5.4
6.60
2.9
Models CSA196 / CSA20
NG – 1.00 kPa
Nominal gas
Turn-down gas
consumption
consumption
(MJ/h)
(MJ/h)
5.30
1.4
6.60
1.4
9.00
2.4
15.00
4.3
6.60
2.9
Injector
(mm)
0.62
0.70
0.82
1.05
0.70
Injector
(mm)
1.00
1.15
1.35
1.75
1.15

Advertisement