Arrangement Of Burners; Final Operations - Smeg SCB 60 Manual

Table of Contents

Advertisement

12.3 Arrangement of burners

Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid

12.4 Final operations

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the pan stands.
Following adjustment to a gas other than the one originally set in the factory, replace the gas adjustment
label fixed to the appliance with the one corresponding to the new gas. The label is inserted inside the
nozzle pack (where present).
12.4.1Adjusting the hob burner minimum setting for city or natural gas
Light the burner and turn it to the minimum position.
Extract the gas tap knob and turn the adjustment screw
next to the tap rod (depending on the model) until the
correct minimum flame is achieved. Refit the knob and
verify that the burner flame is stable (when turning the
knob rapidly from the maximum to the minimum position
the flame must not go out). Repeat the operation on all
gas taps.