8.4.10.3

TIME SINCE LAST CALIBRATION (4.10.2.)

Time elapsed since last calibration. Can be reset to zero after performing a calibration. Can
be reset locally by entering 0 in this parameter.
To reset to zero:
● In SIMATIC PDM, open the menu Device – Maintenance, click on the Calibration
Schedule tab, and click on Calibration Performed to restart the timer and clear any fault
messages.
● Via the handheld programmer, manually reset Time since Last Calibration (4.8.1.) to zero.
8.4.10.4

TIME UNTIL NEXT CALIBRATION (4.10.3.)

Read only. CALIBRATION INTERVAL (4.10.1.) (Page 130) less TIME SINCE LAST
CALIBRATION (4.10.2.) (Page 131).
8.4.10.5

REMINDER ACTIVATION (4.10.4.)

Note
Access
To modify this parameter via SIMATIC PDM it must be accessed via the pull-down menu
Device > Maintenance.
Factory setting:
Setting range:
Purpose:
Description:
8.4.10.6

REMINDER 1 (REQUIRED) (4.10.5.)

Factory setting:
Setting range:
Purpose:
Description:
LR560 (PROFIBUS PA)
Operating Instructions, 06/2018, A5E34648471-AE
Timer OFF
Timer OFF
ON NO LIMITS
ON REMinders 1 and 2 checked
ON REMinder 2 (Maintenance Demanded) checked
Allows you to enable a maintenance reminder.
1. First set the values in REMINDER 1 (REQUIRED) (4.10.5.) (Page 131)
REMINDER 2 (DEMANDED) (4.10.6.) (Page 132).
2. Select the desired Reminder Activation option.
0.164 years
0 to 20 years
If TIME UNTIL NEXT CALIBRATION (4.10.3.) (Page 131) is equal to or
less than this value, the device generates a Maintenance Required remind-
er.
1. Modify values as required.
2. Set REMINDER ACTIVATION (4.10.4.) (Page 131) to the desired op-
tion.
Parameter Reference
8.4 SERVICE (4.)
131