Removal Of Pcbs - Daikin FTE09MV2S Service Manual

Removal procedure. 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of PCBs

6. Removal of PCBs
Procedure
Step
1. Remove the shield plate.
1
The figure shows the
appearance of the
electrical box.
2
Open the shield plate.
3
Push the upper center
of the shield plate and
unfasten the 2 hooks.
Remove the shield
plate.
2. Release the indoor heat
exchanger thermistor.
Release the indoor heat
1
exchanger thermistor
and the earth wire from
the hooks.
14
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Shield plate
Hook
Earth wire
Clamp
Preparation
Signal receiver unit
(R12736)
Hook
(R13208)
Hook
(R4352)
Indoor heat
exchanger
thermistor
(R4353)
Si041138
Points
Remove the electrical box
according to the "Removal of
Electrical Box."
Removal Procedure