7. Removal of Drain Pan Unit / Swing Motor

Procedure
Step
1. Remove the drain pan
unit.
Lift up the indoor unit
1
slightly and pull out the
drain hose. (In the case
of left piping)
Remove the screw at
2
the right side of the
drain pan unit.
3
Press the right side of
the drain pan unit and
twist the left side.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Drain hose
Removal of Drain Pan Unit / Swing Motor
Preparation
Wooden base
(R4374)
(R4375)
Keep
pressing
here
Drain pan unit
Twist here
(R12547)
(R4377)
Points
Remove the electrical box
according to the "Removal of
Electrical Box."
Inserting of the wooden base
facilitates the removing
work.
Place a plastic sheet under
the drain pan to prevent from
wetting the floor with
remaining drain.