Removal of Indoor Heat Exchanger
Step
2. Remove the indoor unit.
1
Remove the indoor unit
from the installation
plate.
3. Remove the indoor heat
exchanger.
1
Unfasten the hook of
the piping fixture at the
back of the indoor unit
and pull out the piping.
2
Slightly widen the
auxiliary piping.
3
Unfasten the upper
hook (left) with a flat
screwdriver.
26
Procedure
Upper hook
(left)
(R4400)
Piping fixture
(R4401)
(R17475)
When removing or
reassembling the indoor heat
exchanger, be sure to wear
protective gloves or wrap the
indoor heat exchanger with
cloths. (You may be injured
by the fins.)
Lower hook
(left)
(R4403)
Si041138
Points
Caution
Removal Procedure