■When the communication destination is Panasonic (FP7 series)
Type
*1
Bit device
Word device
*1 The device is displayed in units of words. (One point corresponds to one word.)
*2 The upper three digits of the device number show the program block number, and the lower six digits show the device number.
■When the communication destination is YASKAWA MP3000 series
Type
*1
Bit device
Word device
*1 The device is displayed in units of words. (One point corresponds to one word.)
*2 The setting can be made only when the communication pattern is "Read".
■When the communication destination is YASKAWA MP2000 series
Type
*1
Bit device
Word device
*1 The device is displayed in units of words. (One point corresponds to one word.)
*2 The setting can be made only when the communication pattern is "Read".
Applicable device
Symbol
WX
WY
WR
WL
_WX
_WY
_WR
_WL
LD
DT
_LD
_DT
Applicable device
Symbol
*2
IB
OB
MB
GB
SB
*2
IW
OW
MW
GW
SW
Applicable device
Symbol
*2
IB
MB
*2
IW
MW
1.15 Simple CPU Communication Function (RJ71EN71, RnENCPU (Network Part))
Range
0 to 511
0 to 511
0 to 2047
0 to 1023
*2
001000000 to 468000511
*2
001000000 to 468000511
*2
001000000 to 468002047
*2
001000000 to 468001023
0 to 16383
0 to 999423
*2
001000000 to 468016383
*2
001000000 to 468065534
Range
0H to 21FFFH
0H to 21FFFH
0 to 1048575
0 to 2097151
0 to 65534
0H to 21FFFH
0H to 21FFFH
0 to 1048575
0 to 2097151
0 to 65534
Range
0H to 7FFFH
0 to 65534
0H to 7FFFH
0 to 65534
1
1 FUNCTIONS