AC
adapter
Figure 31. How to Connect the Tester to a PC

Use an Updated Main Tester to Update Other Testers

1
Turn on both testers and connect the AC adapters to both
testers.
2
Use the USB cable provided to connect the updated main unit
to the remote or to another main. See Figure 32.
3
Follow the instructions shown on the display of the updated
main unit.
If a remote has newer software than the main
unit, the main unit can install the older software
in the remote so that you can use the two units
together. The remote cannot install the newer
software in the main unit.
Micro-AB
USB port
Note
Chapter 7: Maintenance
Update the Software
Type A
USB port
BK46.EPS