Error Codes And Descriptions - Daikin REYQ-TA Series Service Manual

Heat recovery 60 hz
Table of Contents

Advertisement

Service Check Function
2.3

Error Codes and Descriptions

Error code
A0
Indoor Unit
A1
A3
A6
A7 (∗1)
A8
A9
AF (∗1)
AJ
C1
C4
C5
C6
C9 (∗2)
CA
CC
CE (∗1)
CJ (∗2)
E1
Outdoor Unit
E3
E4
E5
E6
E7
E9
F3
F4
F6
H3
H7
H9
J3
J5
J6
J7
J8
J9
JA
167
Operation
lamp
l
External protection device abnormality
l
Indoor unit PCB abnormality
l
Drain level control system abnormality
l
Fan motor lock, overload
Indoor fan motor abnormality
Overload/overcurrent/lock of indoor fan motor
Blower motor not running
Indoor fan motor status abnormality
Low indoor airflow
k
Swing flap motor abnormality
l
Power supply voltage abnormality
Blower motor stops for over/under voltage
l
Electronic expansion valve coil abnormality, dust clogging
k
Drain level above limit
l
Capacity determination device abnormality
l
Transmission abnormality between indoor unit PCB and fan PCB
Blower motor communication error
l
Heat exchanger liquid pipe thermistor abnormality
l
Heat exchanger gas pipe thermistor abnormality
l
Combination error between indoor unit PCB and fan PCB
Blower motor HP mismatch
Indoor blower does not have required parameters to function
l
Suction air thermistor abnormality
Remote sensor abnormality
l
Discharge air thermistor abnormality
k
Humidity sensor system abnormality
k
Infrared presence/floor sensor error
k
Remote controller thermistor abnormality
l
Outdoor unit main PCB abnormality
l
Actuation of high pressure switch
l
Actuation of low pressure sensor
l
Inverter compressor motor lock
l
Compressor damage alarm
l
Outdoor fan motor abnormality
l
Electronic expansion valve coil abnormality
l
Discharge pipe temperature abnormality
l
Wet alarm
l
Refrigerant overcharged
l
Harness abnormality (between outdoor unit main PCB and inverter PCB)
l
Outdoor fan motor signal abnormality
l
Outdoor air thermistor (R1T) abnormality
l
Discharge pipe thermistor (R21T, R22T, R2T) abnormality
Compressor body thermistor (R14T) abnormality
l
Compressor suction thermistor (R12T) abnormality
Suction air thermistor (R10T) abnormality
l
Heat exchanger deicer thermistor (R11T) abnormality
Heat exchanger gas pipe thermistor (R8T, R9T) abnormality
l
Receiver inlet thermistor (R3T) abnormality
Subcooling heat exchanger liquid pipe thermistor (R7T) abnormality
l
Heat exchanger liquid pipe thermistor (R4T, R5T) abnormality
l
Subcooling heat exchanger gas pipe thermistor (R6T) abnormality
Receiver gas purge thermistor (R13T) abnormality
l
High pressure sensor abnormality
Error contents
SiUS371614E
k: ON
h: OFF
l: Blink
Reference
page
170
172
173
175
178
182
183
184
185
186
188
189
190
191
192
193
195
196
196
197
198
199
196
200
196
201
202
207
208
209
211
212
214
216
218
219
221
222
223
224
225
225
225
225
225
225
225
227
Service Diagnosis

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents