HP 8719ET Reference Manual page 132

Network analyzers
Hide thumbs Also See for HP 8719ET:
Table of Contents

Advertisement

MODE MENU
MODE OFF
REF = 1
REF = 2
REF = 3
REF = 4
REF = 5
REF =
FIXED MKR
The second function of this key is to move marker
information off of the graticules so that the display traces
are clearer. If there are two or more markers activated on
a channel on the right side of the display, pressing
will turn off the softkey menu and move the marker
information into the softkey display area. Pressing
or any hardkey which brings up a menu, or a softkey, will
restore the softkey menu and move the marker
information back onto the graticules.
goes to the delta marker menu, which is used to read the
difference in values between the active marker and a
reference marker.
turns off the delta marker mode, so that the values
displayed for the active marker are absolute values.
establishes marker 1 as a reference. The active marker
stimulus and response values are then shown relative to
this delta reference. Once marker 1 has been selected as
the delta reference, the softkey label
underlined in this menu, and the marker menu is
returned to the screen. In the marker menu, the first key
is now labeled
MARKER
"∆REF=1" appears at the top right corner of the graticule.
makes marker 2 the delta reference. Active marker
stimulus and response values are then shown relative to
this reference.
makes marker 3 the delta reference.
makes marker 4 the delta reference.
makes marker 5 the delta reference.
sets a user-specified fixed reference marker. The stimulus
and response values of the reference can be set arbitrarily,
and can be anywhere in the display area. Unlike markers
1 to 5, the fixed marker need not be on the trace. The fixed
marker is indicated by a small triangle ∆, and the active
marker stimulus and response values are shown relative
to this point. The notation "∆REF=∆" is displayed at the
top right corner of the graticule.
Pressing this softkey turns on the fixed marker. Its
stimulus and response values can then be changed using
the fixed marker menu, which is accessed with the
FIXED MKR POSITION
Alternatively, the fixed marker can be set to the current
active marker position, using the
the marker menu.
Hardkey/Softkey Reference
Analyzer Functions
REF = 1
. The notation
REF = 1
softkey described below.
MKR ZERO
,
is
softkey in
5-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp 8720etHp 8719esHp 8722etHp 8720es8722es

Table of Contents