Service Manual
Operator's Compartment
How to R emove the Gauge Clus ter Ass em bly
How to Remove the Gauge
Cluster Assembly
1
Disconnect the battery from the machine.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
2
Remove the fasteners securing the
transmission control lever to the column.
Carefully separate the lever from the column.
3
Grasp the edge of the dash cluster and pull
the cluster through the opening in the
dashboard.
4
Tag and disconnect the wire harness from the
dash cluster. Remove the dash cluster from
the machine.
76
How to R emove the Di agnostic Displ ay
How to Remove the Gauge
Cluster Assembly
1
Disconnect the battery from the machine.
2
Reach under the dashboard and gently loosen
and remove the locknut securing the
diagnostic display to the dashboard. Gently
push the diagnostic display through the
opening in the dashboard.
3
Tag and disconnect the wire harness from the
diagnostic display. Remove the diagnostic
display from the machine.
GTH-1048 • GTH-1056
March 2016
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Part No. 123701