March 2016
Checklist D Pr ocedur es
D-1 Inspec t the F orks
D-1

Inspect the Forks

Genie specifications require that this procedure be
performed every 1000 hours or annually,
whichever comes first OR whenever permanent
deformation of the forks is suspected.
Maintaining the lifting forks in good condition is
essential to safe operation and good machine
performance. Failure to detect damage to the forks
could result in a hazardous operating condition.
1
Thoroughly clean the lifting forks.
2
Inspect the forks for the following:
• Surface cracks
• Straightness of the blade and shank
• Fork angle at 90 ± 3 degrees
• Relative height of fork tips shall not differ
more than 3% of blade length
Fork
48" forks
60" forks
72" forks
• Excessive wear to the forks, fork mount or
legible markings
Result: If any of the above criteria are not met,
the fork shall be removed from service until it
is repaired or replaced.
1 shank
2 blade
Part No. 123701
D-2 Perform Transmissi on Mai ntenance - Dana Models
D-2
Perform Transmission
Maintenance - Dana Models
Transmission specifications require that this
procedure be performed every 1000 hours or
annually, whichever comes first.
Required maintenance procedures and additional
transmission information is available in the Dana
T20000 Maintenance Manual.
Dana T20000 Service Manual
Genie part number
3% of blade length
1.44 in
1.8 in
2.16 in
GTH-1048 • GTH-1056