Figure 59 - Sample Printout (Security Log Report); Figure 60 - Sample Printout (Trend Data New Or Existing Points); Figure 61 - Sample Printout (Custom Screen Report) - York YST Operation Manual

Steam turbine drive centrifugal liquid chiller with optiview control center design level f and g
Hide thumbs Also See for YST:
Table of Contents

Advertisement

FORM 160.67-O1
ISSUE DATE: 4/1/2015
YORK SetpOint Change lOg
ChilleR id 0
(c) 1997 – 2001 YORK INTERNATIONAL CORPORATION
Fri 05 Oct 2001 4:48:04 PM
Log Entry 1 Evaporator - Leaving Chilled Local Setpoint
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
Log Entry 2 Condenser - High Pressure Warning Threshold
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
Log Entry 3 Condenser - Drop Leg
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
Log Entry 4 Evaporator - Refrigerant
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
figure 59 - SAMPLE PRINTOUT (SECURITY LOG
REPORT)
JOHNSON CONTROLS
= 05 Oct 2001
= 4:23:49 PM
= Service
= 4268
= 46.5 ~F
= 48.0 ~F
= 05 Oct 2001
= 1:36:12 PM
= Service
= 4268
= 162.5 Psig
= 225.0 Psig
= 05 Oct 2001
= 1:36:02 PM
= Service
= 4268
= Disabled
= Enabled
= 05 Oct 2001
= 1:35:48 PM
= Service
= 4268
= Disabled
= Enabled
YORK tRend
ChilleR id 163
© 1997 – 2000 YORK INTERNATIONAL CORPORATION
Mon 09 Oct 2000 3:33:47 PM
Data 1: Leaving Chilled Liquid Temperature
Data 2: Return Chilled Liquid Temperature
Data 3: Evaporator Pressure
Data 4: Leaving Condenser Liquid Temperature
Data 5: Return Condenser Liquid Temperature
Data 6: Condenser Pressure
TiMe
daTa 1
daTa 2
daTa 3
3:33:47 PM
45.5 °F
55.0 °F
39.0 PSIG
3:33:48 PM
45.5 °F
55.0 °F
39.0 PSIG
3:33:49 PM
45.5 °F
55.0 °F
39.0 PSIG
3:33:50 PM
45.5 °F
55.0 °F
39.0 PSIG
3:33:51 PM
45.5 °F
55.2 °F
39.1 PSIG
figure 60 - SAMPLE PRINTOUT (TREND DATA
NEW OR EXISTING POINTS)
YORK CUStOm View
ChilleR id 0
(c) 1997 – 2001 YORK INTERNATIONAL CORPORATION
Mon 21 Jun 1999 1:28:25 PM
Leaving Chilled Liquid Temperature
Return Chilled Liquid Temperature = 55.0 ~F
Leaving Condenser Liquid Temperature
Return Condenser Liquid Temperature
Evaporator Saturation Temperature = 41.0 ~F
Condenser Saturation Temperature
Evaporator Pressure
Condenser Pressure
Oil Pressure
figure 61 - SAMPLE PRINTOUT (CUSTOM
SCREEN REPORT)
SECTION 3 - PRINTERS
3
daTa 4
daTa 5
daTa 6
95.0 °F
85.0 °F
120.0 PSIG
95.0 °F
85.0 °F
120.0 PSIG
95.0 °F
85.0 °F
120.0 PSIG
95.0 °F
85.3 °F
120.1 PSIG
95.1 °F
85.4 °F
120.2 PSIG
= 45.0 ~F
= 95.0 ~F
= 85.0 ~F
= 78.5 ~F
= 70.0 Psig
= 140.0 Psig
= 45.0 Psid
161