Figure 58 - Sample Printout (History) - York YST Operation Manual

Steam turbine drive centrifugal liquid chiller with optiview control center design level f and g
Hide thumbs Also See for YST:
Table of Contents

Advertisement

FORM 160.67-O1
ISSUE DATE: 4/1/2015
YORK hiStORY 1
ChilleR id 0
(c) 1997 - 2004 YORK INTERNATIONAL CORPORATION
Tue 20 Apr 2004
3:20:19 PM
SYSTEM RUN
LOCAL STOP
Controls C.E09.12.00.000.00.551
Run Time
0 Days
0 Hr
Operating Hours
Number Of Starts
Control Source
Evaporator
-------------------------------------------------------
Leaving Chilled Active Setpoint
Chilled Liquid Pump Start Contact
Chilled Liquid Flow Switch
Leaving Chilled Liquid Temperature
Return Chilled Liquid Temperature
Evaporator Pressure
Evaporator Saturation Temperature
Evaporator Refrigerant Temperature
Small Temperature Difference
Condenser
------------------------------------------------------
Condenser Liquid Pump Start Contact
Condenser Liquid Flow Switch
Leaving Condenser Liquid Temperature
Return Condenser Liquid Temperature
Condenser Pressure
Condenser Saturation Temperature
Small Temperature Difference
Drop Leg Refrigerant Temperature
Sub Cooling Temperature
Compressor
-------------------------------------------------------
Discharge Temperature
Oil Sump
-------------------------------------------------------
Oil Pump Run Output
Sump Oil Pressure (LOP)
Pump Oil Pressure (HOP)
Oil Pressure
Oil Sump Temperature
Oil Heater Output
Oil Return Solenoid
Variable Speed Oil Pump
-------------------------------------------------------
Oil Pump Drive Command Frequency
25.0 Hz
Variable Speed Oil Pump Control Mode
Auto
Proximity Probe
-------------------------------------------------------
High Speed Thrust Bearing Proximity Different = 2 Mils

figure 58 - SAMPLE PRINTOUT (HISTORY)

JOHNSON CONTROLS
33 Min
=
65 Hr
=
5
= Local
=
42.1 ~F
= Closed
= Closed
=
42.0 ~F
=
58.0 ~F
=
34.5 Psig
=
39.4 ~F
=
40.0 ~F
=
2.0 ~F
= Closed
= Closed
=
94.3 ~F
=
85.0 ~F
= 116.3 Psig
=
96.2 ~F
=
1.9 ~F
=
90.0 ~F
=
6.2 ~F
= 120.0 ~F
= On
=
33.1 Psig
=
89.4 Psig
=
56.5 Psid
= 136.5 ~F
= On
= On
=
=
Subcooler Level
-------------------------------------------------------
Subcooler Level Setpoint
Subcooler Level Pulldown Time Remaining
Subcooler Level
Control Output Signal
Subcooler Level Auto/Manual Mode
Auto
Hot Gas Bypass
--------------------------------------------------------
Hot Gas Ratio Calculation
Temp Setpoint
Hot Gas Temp Calculation
HGV Ramp
Control Output Signal
HGV Auto/Manual Mode
Pre-Rotation Vanes
-------------------------------------------------------
PRV Position
PRV Ramp
PRV Command
PRV Motor Switch
PRV Auto/Manual Mode
Speed Control
--------------------------------------------------------
Speed Setpoint
MSSP7 - Speed Control Mode
Turbine Speed
Control Output Signal
Turbine Rotation
Speed Setpoint Auto/Manual Mode
Steam Control
-------------------------------------------------------
Inlet Temperature
Inlet Pressure
First Stage Pressure
Exhaust Pressure
Inlet Solenoid
Inlet Valve
Bypass Solenoid
Inlet Limit Switch
Slow Roll Valve
Governor End Bearing Temperature
Shaft End Bearing Temperature
Turbine Vibration Sensor
--------------------------------------------------------
Governor End Horizontal Vibration
Governor End Vertical Vibration
Shaft End Horizontal Vibration
Shaft End Vertical Vibration
Turbine Solenoids
-------------------------------------------------------
Turbine Rotation
Trip Solenoid
Trip Valve Limit Switch
Vacuum Solenoid
Inlet Limit Switch
SECTION 3 - PRINTERS
=
50 %
=
0 Sec
=
50 %
=
100 %
3
=
=
100 %
=
41.0 ~F
=
0 %
=
90 %
=
100 %
= Auto
=
0 %
=
7 %
=
7 %
= Open
= Auto
=
0 RPM
= Variable Speed
=
4276 RPM
= 100.0 %
= Open
= Auto
= 358.0 ~F
> 358.0 Psig
=
41.0 Psig
=
1.6 Psia
= ~F
=
100 %
= Off
= Closed
=
0 %
= 170.1 ~F
= 150.2 ~F
=
0.5 Mils
=
0.5 Mils
=
0.5 Mils
=
0.5 Mils
= Open
= On
= Closed
= On
= Closed
159