2.5.5 JP2: internal pulse (DDA) 5V ground and external +24V ground
2
This section introduces the PCI-M324 motion control card using the short-circuit latch for
common or individual grounding for the 5V ground and external ground signal.
The following table shows the JP2 pin definition:
Pin
1
2
3
2-12
signal jumper
Mark
Not in use
IGND
EGND
Description
Reserved (not in use)
DDA pulse ground signal
24V ground signal