motor & electrical
symptom
possible cause
motor will not
1. emergency off button depressed.
start or fuses or
2. short circuit in line cord or plug.
circuit breakers
blow.
3. start capacitor is at fault.
4. thermal protection circuit breaker amperage
is set too low or motor is at fault.
5. open circuit in motor or loose connections.
motor fails to
1. motor run capacitor at fault.
develop full
2. motor overloaded during operation.
power or motor
3. air circulation through the motor restricted.
decreases
4. motor overloaded during operation.
rapidly with
5. thermal protection circuit breaker amperage
load, overheats,
is set too low or motor is at fault.
or stalls.
6. short circuit in motor or loose connections.
7. Circuit breaker tripped.
Cutterhead
1. v-belt loose.
slows or
2. v-belt worn out.
squeals
when cutting,
especially on
start-up.
loud repetitious
1. pulley set screws or keys are missing or
noise coming
loose.
from machine.
2. v-belts are damaged.
3. motor fan is hitting the cover.
-46-

troubleshooting

possible solution
1. rotate clockwise until it pops out/replace.
2. repair or replace cord or plug for damaged insulation
and shorted wires.
3. replace start capacitor.
4. unplug machine, open magnetic switch cover, turn
amperage dial on thermal protection Circuit Breaker
to a higher amperage setting. if dial cannot be set any
higher, replace motor.
5. inspect all lead connections on motor for loose or
open connections.
1. replace run capacitor.
2. reduce cutting load; take lighter cuts.
3. Clean out motor to provide normal air circulation.
4. reduce cutting load; take lighter cuts.
5. unplug machine, open magnetic switch cover, turn
amperage dial on thermal protection Circuit Breaker
to a higher amperage setting. if dial cannot be set any
higher, replace motor.
6. repair or replace connections on motor for loose or
shorted terminals or worn insulation.
7. install correct circuit breaker; reduce number of
machines running on that circuit.
1. tension v-belt (page 48).
2. replace v-belt (page 48).
1. inspect keys and set screws. replace or tighten if
necessary.
2. replace v-belts (page 48).
3. adjust fan cover mounting position, tighten fan, or
shim fan cover.