Direct Current (Dc) Power Interface (Optional); Figure 3-5. Cdd-56Xa/L Dc Power Interface; Figure 3-6. Applying Dc Power To The Cdd-56Xa/L - Comtech EF Data CDD-562AL Installation And Operation Manual

Multi-channel demodulator
Table of Contents

Advertisement

CDD-562AL/564A/L Multi-Channel Demodulator
Rear Panel Connections
3.3.3
48V Direct Current (DC) Power Interface (Optional)
Input Power
Input Voltage
Connector Type
Mating Connector
Fuse Protection
3.3.3.1
DC Operation – Applying Power

Figure 3-6. Applying DC Power to the CDD-56xA/L

To apply DC power to the CDD-56xA/L:
1. Assemble the user-supplied red (+) and black (–) DC power leads and their crimped terminals
into the shell of the module mating connector.
a. Number 18 AWG minimum wires are recommended.
b. Note the keyed orientation for the wires.
2. Connect the user-supplied DC power leads to the power source.
3. Plug the connector into the keyed module socket as shown.
1 Plug-in Power Receptacle

Figure 3-5. CDD-56xA/L DC Power Interface

DC Power Specifications
48 W (typical)
106 W (maximum)
48 V DC nominal
(36 V to 60 V)
Corcom PS series
Corcom GA210 or Molex 03-12-1026
Line and Neutral Fusing
(2X) 5mm x 20mm Slow-blow type fuses:
T4A (4 Amp)
3–9
Revision 0
MN-CDD562AL564AL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdd-564alCdd-564a

Table of Contents