Advertisement

[MSU] connector (page 26: 6)
HR10G-10R-10SC (71) (Hirose Electric Co., Ltd.)
Pin No.
1
2
3
4
5
6
7
8
9
10
● Connector of cable
HR10A-10P-10P (73)
[MIC1] and [MIC2] connectors (page 26: 7)
HA16RV-3PG(76) (Hirose Electric Co., Ltd.)
Pin No.
1
SHIELD
2
HOT
3
COLD
● When connecting to an unbalanced input terminal of an external device, connect to it as shown in the diagram below.
1 : Ground (Shield)
2 : Hot (+Ve)
3 : Cold (-Ve)
● Some commercially available conversion connectors and conversion cables have pin 3 shorted to pin 1.
Using such a conversion connector or conversion cable will cause a failure.
NG
Function
MSU CONT (H)
MSU CONT (C)
MSU DATA (H)
MSU DATA (C)
TALLY R
TALLY G
HEAD POWER
ALARM 1
ALARM 0
GND
7
6
Function
CCU→SYSTEM
CCU→SYSTEM
XLR connector
2
1
3
Be sure to open pin 3.
2
1
3
Do not use a conversion connector or conversion cable
on which pin 3 is shorted to pin 1.
CCU→MSU
CCU→MSU
MSU→CCU
MSU→CCU
CCU→MSU
CCU→MSU
CCU→MSU
CCU→MSU
CCU→MSU
8
1
10
9
2
3
5
4
Flow of signal
0 dBm, 600 Ω
PIN connector
(unbalanced input connector)
- 128 -
Reference
Flow of signal
Remarks