10

Error messages

.05
If a malfunction occurs, an error code appears on the display. An error message may be
caused by incorrect operation, machine defects, as well as by overload conditions.
(For a description of the error codes see Chapter 14.02 Description of the error codes).
Errors when connecting outputs
If an error occurs when connecting an output, the output concerned is shown with the desi-
red switching state (0) or (I).
In this case (0) means the output should be disconnected and (I) means that the output
should be connected.
In the next line the cause leading to the error is displayed.
The target state for maintaining undisturbed operation is shown in brackets.
In the following example the output Y1.1 is to be connected.
Requirement: E1.1 must be set at (1).
Pocket plate
forwards
Pocket plate
at front
● Check E1.1 and eliminate error.
● Acknowledge elimination of the error..
Sewing
Target state
Pocket plate
forwards
Target state
Pocket plate
at front
53