Pfaff 3588-05/020 Instruction Manual page 148

Table of Contents

Advertisement

Adjustment
148
600
604
Delay time for stacker frame back [0.01s]
The parameter is used to enter the delay time bet-
ween stacker roller roll slowly and stacker frame back.
605
Time for folder slide back [0.01s]
The parameter is used to enter the delay time for the
folder slide.The time should be set so that the folder
does not move up until the folder plate is in its rear
end position.
606
Time for pocket plate open [0.01s]
The parameter is used to enter the delay time bet-
ween pocket plate back and pocket plate open. If the
time selected is 0.00 s, the pocket plate opens when
the end switch pocket plate back (E1.2) is activated.
607
Speed feed unit [%]
The parameter is used to enter the speed of the
sewing jig feed unit from the folding to the sewing
station.
608
Seam correction X [0.01 mm]
This parameter is used to change the position of the
seam on the pocket in x-direction.
609
Seam correction Y [0.01 mm]
This parameter is used to change the position of the
seam on the pocket in y-direction.
610
Stacker cycle
0 = standard
1 = short part
2 = off (basic position retracted)
3 = off (basic position extended)
0 - 999
0
0 - 999
30
0 - 999
50
20 - 100
100
-20 - +20
0
-20 - +20
0
0 - 3
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3588-15/020

Table of Contents