Preadjusting The Needle Height - Pfaff 3588-05/020 Instruction Manual

Table of Contents

Advertisement

Adjustment
13

Preadjusting the needle height

.05.05
● Move needle bar 1 (screws 2) without twisting it according to the requirement.
96
Requirement
At needle bar position TDC, the distance between the needle point and the adjustment
gauge must be approx. 22 mm.
Fig. 13 - 06
2
1
22 mm