Control unit
14

Stacker motor drive

.01.04
Operation controls
14

AC-Line-Controller

.01.05
Default setting
Operation displays
156
Before leaving the factory, the stacker motor drive has been set and/or program-
med to meet the requirements of this machine. It may only be replaced by a
programmed drive.
LED H1 (yellow)
off
on
off
on
fl ashes
The AC-Line-Controller is set in the factory to the requirements of this machine.
An exchange is only permissible after prior adjustments.
Potentiometer
UL (upper limit)
LL (lower limit)
off Delay
LED H1 (green)
off
on
on
LED H2 (green)
off
off
on
on
off
Value
260V
195V
Min
LED H1 (red)
off
off
on
Discription
Power off, no function
Power on, after approx
0,5s of self-test ready for
operation
drive has been started
overload protection active
see
chapter 14.02.06Errors -
Stacker drive
Discription
line off, no function
machine functional,
voltage outside the
set range
machine functional,
voltage within the
set range