Ekhbrd 011/014/016 Ac/Ad(V1/Y1) - Daikin ALTHERMA HT Service Manual

Hide thumbs Also See for ALTHERMA HT:
Table of Contents

Advertisement

ESIE09-08B
2.5

EKHBRD 011/014/016 AC/AD(V1/Y1)

Overview
Legend
Refrigerant Circuit
2 18
17
19
3
No.
Name
1
Air purge valve
2
Thermistors
3
Switchbox
4
Heat exchangers
5
Refrigerant liquid connection R410A
6
Refrigerant gas connection R410A
7
Shut-off valves
8
Water inlet connection
9
Water outlet connection
10
Drain valve
11
Water filter
12
Expansion vessel (12l)
23
20
1
16
10
2 2
22 22
14
4
2
21
4
6
5
13
12
11
No.
13
14
15
16
17
18
19
20
21
22
23
Functional Parts Layout
7 8
15
7
9
Name
Manometer
Pump
Pressure relieve valve
Service ports R134a
Compressor R-134a
Accumulator
3-way valve (option, with EKHTS tank))
4-way valve
Thermal cut-out
Electronic expansion valve
T-piece (option, with EKHTS tank)