Daikin ALTHERMA HT Service Manual page 260

Hide thumbs Also See for ALTHERMA HT:
Table of Contents

Advertisement

External Backup Heater Kit
Safety devices
The heater kit air purge connection may not be used for other purposes.
Caution
 Thermal protector — The heater in the heater kit is equipped with a thermal protector
 The electrical box lid must only be opened by a licensed electrician.
Caution
 Switch off the power supply before opening the electrical box lid.
 Pressure relief valve — In case valves are installed between the indoor unit and the heater
248
(activation temperature 92°C). The thermal protector is activated when the temperature
becomes too high. When activated, the protector has to be reset on the heater of the heater
kit by pressing the white button (for access, remove the cover of the kit).
kit and between the outlet and the load, a pressure relief valve (field supply) in accordance
with relevant local laws and regulations, and with an opening pressure of maximum 3 bar
must be installed on the water inlet of the heater kit.
ESIE09-08B
Appendix

Advertisement

Table of Contents
loading

Table of Contents