Scope Of This Manual; Model Identification; Typical Application Examples; Application Examples With Only 1 Heat Emitter - Daikin EKHBRD011ADV1 Installation Manual

Indoor unit for air to water heat pump system
Hide thumbs Also See for EKHBRD011ADV1:
Table of Contents

Advertisement

Remote controller (option)
An optional secondary EKRUAHTA remote controller (with room
thermostat functionality) can be connected to the indoor unit.
Purpose is to provide the possibility to install the standard remote
controller near the unit (for service reasons), and install another
remote controller in another place (e.g. living room) to operate your
installation.
Refer to the
"Installation of the remote controller" on page 17
further details.
Room thermostat (option)
An optional room thermostat EKRTR or EKRTW can be connected to
the indoor unit.
Refer to the room thermostat installation manual for further details.
If this option is installed it is not possible to use the remote
controller thermostat function.
Heater kit (option)
An optional EKBUH heater kit can be combined with the indoor unit.
Purpose is to provide an additional heating capacity during cold
outdoor temperatures. The heater kit has a heating capacity of 6 kW,
and available for both 1-phase and 3-phase power supply
specifications. When using this heater kit, installation of the optional
demand PCB is required as well.
Refer to the heater kit installation manual for further details.
P
H
2
3
1
1
Heat pump capacity
2
Required heating capacity (site dependent)
3
Additional heating capacity provided by the heater kit
T
Ambient (outdoor) temperature
A
P
Heating capacity
H
Digital I/O PCB (option)
An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs.
Refer to the operation manual of the indoor unit and to the digital I/O
PCB installation manual for more information.
Refer to the wiring diagram or connection diagram for connecting this
PCB to the unit.
Demand PCB (option)
An optional EKRP1AHTA demand PCB can be connected to the
indoor unit. This PCB is needed when the optional heater kit EKBUH
or Daikin room thermostat EKRTR or EKRTW is installed or when
multiple set point control is used, and provides the communication
with the indoor unit.
Refer to the demand PCB installation manual for further details.
Refer to the wiring diagram or connection diagram for connecting this
PCB to the unit.
EKHBRD011~016ADV1+Y1
Indoor unit for air to water heat pump system
4P402191-1A – 2015.04

Scope of this manual

This installation manual describes the procedures for handling,
installing and connecting all EKHBRD indoor unit models.
NOTE
for
Model identification
Indoor unit
EK

Typical application examples

The application examples given below are for illustration purposes
only.
Application examples with only 1 heat emitter and 1
heat source (EKHBRD unit)
If only 1 heat emitter (= all system has 1 water set point), it is
recommended NOT to use a balancing bottle.
Using a balancing bottle will affect the optimal pump control of the
unit and will increase the cost of the system unnecessarily.
I
T
A
Installation of the ERSQ or ERRQ heat pump outdoor
is described in the outdoor unit installation manual.
Operation of the indoor unit is described in the indoor
unit operation manual.
HBR
D
016
AD
Series
Indication of heating capacity (kW)
Refrigerant type R134a
Hydro box - high temperature heating only
European kit
(a) For exact values, refer to
"Unit specifications" on page
Application 1
Space heating and domestic hot water heating with a single
remote controller installed in the living room.
1
12
2
3
12
4
M
5
8
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat
exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
V1
V1=1N~, 220-240 V, 50 Hz
Y1=3N~, 380-415 V, 50 Hz
(a)
38.
A
B
C1
6
7 10 13
11
9
9
Domestic hot water
tank (optional)
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion
valve
13
By-pass valve (field
supply)
C1
Remote controller
A
Installation place
B
Living room
Installation manual
2