Daikin ALTHERMA HT Service Manual page 175

Hide thumbs Also See for ALTHERMA HT:
Table of Contents

Advertisement

ESIE09-08B
1: Coil check method for the moving part of the electronic expansion valve
Disconnect the electronic expansion valve from the PC board and check the continuity between
the connector pins.
(Normal)
1. White
2. Yellow
3. Orange
4. Blue
5. Red
6. Brown
: Continuity
×: No continuity
Troubleshooting
Pin No.
1. White
Troubleshooting by Indication on the Remote Controller
(White) 1
(Yellow) 2
(Orange) 3
(Blue) 4
(Red) 5
(Brown) 6
(V3067)
2. Yellow
3. Orange
×
Approx.
300
×
4. Blue
5. Red
×
Approx.
150
×
Approx.
300
×
Approx.
150
×
6. Brown
×
Approx.
150
×
Approx.
150
×
163

Advertisement

Table of Contents
loading

Table of Contents