4.2 Connecting the cables

Warning
If the housing is not perfectly sealed and the HiPath Wireless Outdoor AP is subjected to spray
water or dampness, you will endanger your life. Ensure that you adhere to the following safety
rules.
• Before connecting up, turn off the power supply.
• The sealing of the cable feedthroughs of the HiPath Wireless Outdoor AP is only assured when
the cable has a suitable diameter and adequate tensile strength. Only use cables that meet the
specifications as mentioned in
• Never wrap insulating tape, adhesive tape or other materials around thinner cables to achieve
the required diameter. In this case, neither the housing seal nor the strain relief clamps can fulfill
their function
• Close all unused openings in the housing seal with the sealing plugs supplied with the Outdoor
Wireless. Do not use fillers or any other material under any circumstances
9034532, October 2009
HiPath Wireless Outdoor AP Installation Guide
Connecting cables to the HiPath Wireless Outdoor AP
Length in m
0,3
2
Table 6
Antenna connector: R-SMA Male to SMA Male connecting cable
Section 4.1, "HiPath Wireless Outdoor AP cables", on page
To connect the cables to the HiPath Wireless Outdoor AP.
1. Connect the cables to the appropriate contacts. (Position A in
Figure 17
Connecting a cable and fitting the strain relief clamps
OutdoorAP_ConnectingUp.fm
Connecting the cables
Order number (ordered from Siemens A&D)
6XV1875-5DE30
6XV1875-5DH20
29.
Figure
17.)