Error Messages - DURKOPP ADLER 559 Instruction Manual

Sewing automat
Table of Contents

Advertisement

Available languages

Available languages

25. Error messages

Error
1051
1052
1053
1055
1056
1058
1062
1302
1342
-
1344
2101
2152
2153
64
Info/Description
Sewing motor timeout
· Cable to the sewing motor
reference switch faulty
· Reference switch defective
Sewing motor excess current
· Cable of sewing motor faulty
· Sewing motor defective
· Control defective
Too high mains voltage
Sewing motor overcharge
· Sewing motor blocked/moves
too heavy
· Sewing motor defective
· Control defective
Sewing motor excess
temperature
· Sewing motor moves too
heavy
· Sewing motor defective
· Control defective
Sewing motor speed
Sewing motor defective
Sewing motor IDMA
Autoincrement
Malfunction
Sewing motor: current supply
fault
Encoder cable not connected /
defective
Encoder defective
Sewing motor fault
Internal fault
Step motor X-axis timeout
reference
· Cable to the reference switch
faulty
· Reference switch defective
Step motor X-axis excess
current
Step motor X-axis excess
voltage
Too high mains voltage
Remedy
· Replace the cable
· Replace the reference switch
· Replace the sewing motor cable
· Replace the sewing motor
· Replace the control
Check mains voltage
· Eliminate the blocking/rough
running
· Replace the sewing motor
· Replace the control
· Eliminate the rough running
· Replace the sewing motor
· Replace the control
· Replace the sewing motor
Switch the machine off and on again
· Eliminate the blocking
· Check /
Replace the encoder cable
· Replace the sewing motor
· Switch the machine off
again
· Software update
· Inform DA-Service
· Replace the cable
· Replace the reference switch
· Replace step motor X-axis
· Replace the control
Check the mains voltage
and on

Advertisement

Chapters

Table of Contents
loading