Supplemental Information

Using a Roland DIF-AT

With an ADAT

With a Roland DIF-AT, audio can be digitally exchanged between the VS-2480 and an
ADAT recorder, controlling the ADAT from the VS-2480.
1. With the power to all devices turned off, connect the ADAT to the
Connect the ADAT's SYNC IN connector to the SYNC connector on the DIF-AT. This
connection is required for controlling the ADAT remotely from the VS-2480/DIF-AT,
and to transmit MTC from the VS-2480.
2. Turn on the ALESIS ADAT, and then turn on the VS-2480.
3. Press UTILITY.
4. Press PAGE until "R-BUS" appears above F2.
5. Press F2 (R-BUS)—the R-BUS CONFIG screen appears (Page 377).
6. Activate remote control of the R-BUS jack to which your DIF-AT—and hence the
7. Press the F button for the DIF-AT's R-BUS jack to
8. Set INPUT SELECT to ADAT.
9. Press UTILITY.
10. Press PAGE until "Proj" appears above F3.
11. Press F3 (Proj)—the PROJECT PARAMETER screen
12. Set MASTER CLOCK to INT.
13. Press UTILITY.
14. Press F5 (MIDI)—the display switches to the MIDI PARAMETER screen.
15. Set MMC MODE to MASTER.
16. Press UTILITY.
17. Press F6 (SYNC)—the SYNC PARAMETER screen appears.
18. Set SYNC MODE to INT and set the R-BUS SYNC Gen. parameter for the R-BUS
With a TASCAM DA Series Device
With a Roland DIF-AT, audio can be digitally exchanged between the VS-2480 and a
DA Series—T-DIF—device, with the VS-2480 being controlled by the DA Series device.
A TASCAM DA Series device's word clock cannot be slaved to the VS-2480. It must
provide the master word clock for both devices.
1. With the power to all devices turned off, connect the DA series device to the
Connect the DA Series device's SYNC IN connector to the SYNC connector on the
DIF-AT—its SYNC OUT connector cannot be connected to the DIF-AT.
2. Turn on the TASCAM DA Series device, and then turn on the VS-2480.
3. Press UTILITY.
4. Press PAGE until "R-BUS" appears above F2.
5. Press F2 (R-BUS)—the R-BUS CONFIG screen appears (Page 377).
6. As described on Page 377, activate remote control of the R-BUS jack to which your
388
DIF-AT, and the DIF-AT to the VS-2480.
ADAT—is connected.
display the DIF-AT's settings.
appears.
jack you're using to MTC.
DIF-AT, and the DIF-AT to the VS-2480.
DIF-AT—and hence the DA Series device—is connected.