6.6.3

Message description

The following table shows the priority in which alerts are displayed, error code, alert
level, message, meaning and remedy (where available) for all messages.
Messages which appear in the Alert Log (see section 3.5) are indicated with a " " in
the Alert List column. Messages which do not appear in the Alert Log are indicated
with a " ".
Prio
Error
rity
Code
Alert level: Alarm
1
0001
Communication Error
2
0002
Drive unit malfunction.
Check the drive circuit.
3
0003
Drive unit is overloaded.
Check the drive circuit.
4
0004
Drive unit is overheated.
Check the drive circuit.
5
0005
Rudder drive malfunction.
Check the drive circuit.
6
0006
Rudder angle error.
Check the drive circuit.
Alert level: Warning
7
1001
Reduce speed for SABIKI
(<5kn)
8
1002
Communication error with
EVC system.
9
1003
Communication error be-
tween processor unit and
control unit.
10
1004
No heading data available.
11
1005
Sudden change in heading
data.
12
1006
Rate sensor error.
13
1013
Initializing heading sensor.
This takes two minutes,
please wait.
6-14
Message
A communication error has occurred in
the processor unit. Turn the power off
and request service from your local deal-
er.
A malfunction was detected in the drive
unit. Turn the power off and request ser-
vice from your local dealer.
The system has detected that the drive
unit is overloaded. Turn the power off
and request service from your local deal-
er.
The drive unit has overheated. Turn the
power off and request service from your
local dealer.
A malfunction was detected in the rudder
drive unit. Turn the power off and re-
quest service from your local dealer.
A malfunction was detected in the drive
unit. Turn the power off and request ser-
vice from your local dealer.
You attempted to activate SABIKI mode,
but your vessel's speed is over 5 kn. Re-
duce speed to below 5 kn and try again.
There is a problem with the connection
between the processor unit and the IPS.
Check the connections.
There is a problem in the connection be-
tween the processor unit and control
unit. Check the connections.
No heading data is being received.
Check connection to, and status of, the
heading sensor.
A sudden change in heading data was
detected. Check the status of the head-
ing sensor.
An error message was received from the
heading sensor. Check the status of the
heading sensor.
The heading sensor is being initialized.
Wait until the initialization process is
complete (approx. two minutes).
Meaning/remedy
Alert
Log