4.2.2

Removing Spill Trays

m
Caution
Fragile Component
Porcelain enamel spill trays are fragile.
1. Push each ignition wire downward through its respective
receptacle, as you carefully lift out each spill tray (see Figure 30
and Figure 31).
Figure 30: Typical Spill Tray
Figure 31: Removing the Spill Trays (Ignition Wire Shown)
58300000156573_ARA_EN_B
4.2.3

Removing Heat Shields

Figure 32: Typical Heat Shields
Sharp Components – Gloves Recommended
Use gloves when removing or installing a heat shield, as the edges
may be sharp.
1. Remove and retain the screws that secure the heat shield onto the
range.
2. Use gloves while you carefully lift and remove the heat shield(s).
See Figure 33.
Figure 33: Removing the Heat Shield