Speed/time constant
Fast forward speed
Set the fast forward speed for each axis. Refer to fast forward speed for details. (Page 173 Fast forward speed)
Cutting feed clamp speed
Set the maximum speed for cutting feed rate on each axis. When the feed rate in G01 is commanding a value that exceeds
the cutting feed clamp speed, the speed is clamped at the cutting feed clamp speed that has been set. Refer to cutting feed
speed for details. (Page 174 Cutting feed speed)
G0 time constant (linear)
Set the time constant of linear control in fast forward acceleration/deceleration. Refer to fast forward speed for details.
(Page 173 Fast forward speed)
Speed
G0 time constant
G0 time constant
G1 time constant (linear)
Set the time constant of linear control in cutting feed acceleration/deceleration. Refer to cutting feed speed for details.
(Page 174 Cutting feed speed)
Speed
G1 time constant
G1 time constant
Time
Time
4 G-CODE CONTROL PARAMETERS
4.2 G-Code Control Axis Parameter
4
85