Speed/time constant

Fast forward speed
Set the fast forward speed for each axis. Refer to fast forward speed for details. (Page 173 Fast forward speed)
Cutting feed clamp speed
Set the maximum speed for cutting feed rate on each axis. When the feed rate in G01 is commanding a value that exceeds
the cutting feed clamp speed, the speed is clamped at the cutting feed clamp speed that has been set. Refer to cutting feed
speed for details. (Page 174 Cutting feed speed)
G0 time constant (linear)
Set the time constant of linear control in fast forward acceleration/deceleration. Refer to fast forward speed for details.
(Page 173 Fast forward speed)
Speed
G0 time constant
G0 time constant
G1 time constant (linear)
Set the time constant of linear control in cutting feed acceleration/deceleration. Refer to cutting feed speed for details.
(Page 174 Cutting feed speed)
Speed
G1 time constant
G1 time constant
Time
Time