Details code
Description
0326H
Plane selection in
coordinate rotation
0327H
Incremental value
command after
coordinate rotation
Add-on license error details codes
The detail codes when an add-on license error is detected in G-code control are shown below.
Detailed information 1
■Add-on license warning (warning (error code: 0EF1H)), add-on license minor error (minor
error (error code: 1FF1H)), add-on license moderate error (moderate error (error code:
3081H))
Refer to the following for the details codes for when add-on license warning (warning (error code: 0EF1H)), add-on license
minor error (minor error (error code: 1FF1H)), and add-on license moderate error (moderate error (error code: 3081H)) are
detected.
MELSEC iQ-R Motion Controller Programming Manual (Common)
APPENDICES
242
Appendix 1 G-Code Control Error Details Codes
Error details and cause
A plane selection command (G17, G18, G19) was
commanded during a coordinate rotation command.
The movement command immediately after program
coordinate rotation mode start command (G68), and
program coordinate rotation mode cancel command
(G69) was an incremental value command.
Corrective action
After coordinate rotation command, be sure to execute
a coordinate rotation cancel command before making
a plane selection command (G17, G18, G19).
Make absolute value commands immediately after
program coordinate rotation mode start command
(G68), and program coordinate rotation mode cancel
command (G69).