Chapter 2 High-Speed Counter Module Fb; M+Fx5-2Hc_Countenable (Count Enable Operation); Overview; Labels - Mitsubishi Electric MELSEC iQ-F Series Manual

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

2
HIGH-SPEED COUNTER MODULE FB
2.1
M+FX5-2HC_CountEnable (Count Enable
Operation)

Overview

This FB executes the count operation (Count start/stop) on a specified channel.
M+FX5-2HC_CountEnable
(1)
B:i_bEN
(2)
DUT:i_stModule
(3)
UW:i_uCH

Labels

Input label
No.
Label
Label name
(1)
i_bEN
Execution
command
(2)
i_stModule
Module label
(3)
i_uCH
Target channel
Output label
No.
Label
Label name
(4)
o_bENO
Execution status
(5)
o_bOK
Normal completion
(6)
o_bErr
Error completion
(7)
o_uErrId
Error code
(8)
o_bCountStart
Count in operation flag
(4)
o_bENO:B
o_bErr:B
(5)
o_uErrId:UW
(6)
o_bErr:B
(7)
o_bCountStart:B
(8)
Data type
Import
Bit
Always
Structure
At FB start
Word [Unsigned]/Bit
At FB start
String [16-bit]
Data type
Bit
Bit
Bit
Word [Unsigned]/Bit String
[16-bit]
Bit
Range
Description
On or off
On: The FB is activated.
Off: The FB is not activated.
Specify the module label of the MELSEC iQ-F
high-speed counter module.
1 to 2
1 or 2: Specify the channel number.
Default
Description
value
Off
On: The execution command is on.
Off: The execution command is off.
Off
When this label is on, it indicates that the FB has
been completed normally.
Off
When this label is on, it indicates that an error
has occurred in the FB.
0
Stores the error code that occurred in the FB.
Off
On: The count operation is on.
Off: The count operation is off.
2 HIGH-SPEED COUNTER MODULE FB

2.1 M+FX5-2HC_CountEnable (Count Enable Operation)