Panasonic FP0H User Manual page 109

Programmable controller
Hide thumbs Also See for FP0H:
Table of Contents

Advertisement

WR908 (specification in word units)
Relay No.
Name
R9080
R9081
R9082
R9083
R9084
R9085
R9086
R9087
MEWNET-W0
PLC link 1
transmission
assurance relay
R9088
R9089
R908A
R908B
R908C
R908D
R908E
R908F
10.3 List of Special Relays (COM Communication)
Description
When Unit No.1 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.1
established: OFF
When Unit No.2 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.2
established: OFF
When Unit No.3 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.3
established: OFF
When Unit No.4 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.4
established: OFF
When Unit No.5 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.5
established: OFF
When Unit No.6 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.6
established: OFF
When Unit No.7 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.7
established: OFF
When Unit No.8 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.8
established: OFF
When Unit No.9 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.9
established: OFF
When Unit No.10 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.10
established: OFF
When Unit No.11 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.11
established: OFF
When Unit No.12 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.12
established: OFF
When Unit No.13 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.13
established: OFF
When Unit No.14 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.14
established: OFF
When Unit No.15 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.15
established: OFF
When Unit No.16 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.16
established: OFF
10-15