Panasonic FP0H User Manual page 107

Programmable controller
Hide thumbs Also See for FP0H:
Table of Contents

Advertisement

WR906 (specification in word units)
Relay No.
Name
R9060
R9061
R9062
R9063
R9064
R9065
R9066
R9067
MEWNET-W0
PLC link 0
transmission
assurance relay
R9068
R9069
R906A
R906B
R906C
R906D
R906E
R906F
10.3 List of Special Relays (COM Communication)
Description
When Unit No.1 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.1
established: OFF
When Unit No.2 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.2
established: OFF
When Unit No.3 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.3
established: OFF
When Unit No.4 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.4
established: OFF
When Unit No.5 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.5
established: OFF
When Unit No.6 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.6
established: OFF
When Unit No.7 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.7
established: OFF
When Unit No.8 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.8
established: OFF
When Unit No.9 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.9
established: OFF
When Unit No.10 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.10
established: OFF
When Unit No.11 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.11
established: OFF
When Unit No.12 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.12
established: OFF
When Unit No.13 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.13
established: OFF
When Unit No.14 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.14
established: OFF
When Unit No.15 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.15
established: OFF
When Unit No.16 is normally communicating in PLC link mode: ON
Unit
When the unit is stopped, an error has occurred, or PLC link is not
No.16
established: OFF
10-13