Table 25 Primary node cabling instructions
String
I/O - Port
(Loop)
1
I/O 6 - Port 0 A controller port 0 of shelf V1.1
1
I/O 2 - Port 1 B controller port 0 of the highest number shelf in V1
2
I/O 3 - Port 0 A controller port 0 of shelf V2.1
2
I/O 2 - Port 0 B controller port 0 of the highest number shelf in V2
3
I/O 2 - Port 2 A controller port 0 of shelf V3.1
3
I/O 3 - Port 2 B controller port 0 of the highest number shelf in V3
4
I/O 2 - Port 3 A controller port 0 of shelf V4.1
4
I/O 6 - Port 1 B controller port 0 of the highest number shelf in V4
5
I/O 6 - Port 3 A controller HOST
5
I/O 3 - Port 3 B controller HOST
6
I/O 9 - Port 3 A controller HOST
6
I/O 6 - Port 2 B controller HOST
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Table 26 Standby node cabling instructions
String
I/O - Port
(Loop)
1
I/O 6 - Port 0 B controller port 2 of shelf V1.1
1
I/O 2 - Port 1 A controller port 2 of the highest number shelf in V1
2
I/O 3 - Port 0 B controller port 2 of shelf V2.1
2
I/O 2 - Port 0 A controller port 2 of the highest number shelf in V2
3
I/O 2 - Port 2 B controller port 2 of shelf V3.1
3
I/O 3 - Port 2 A controller port 2 of the highest number shelf in V3
4
I/O 2 - Port 3 B controller port 2 of shelf V4.1
4
I/O 6 - Port 1 A controller port 2 of the highest number shelf in V4
5
I/O 6 - Port 3
5
I/O 3 - Port 3
Shelf Port
port of the SSD shelf or DD
Cloud Tier metadata shelf
port of the SSD shelf or DD
Cloud Tier metadata shelf
port of the SSD shelf or DD
Cloud Tier metadata shelf
port of the SSD shelf or DD
Cloud Tier metadata shelf
Shelf Port
A controller EXPANSION
or DD Cloud Tier metadata shelf
B controller EXPANSION
or DD Cloud Tier metadata shelf
DD9500 and DD9800 with DD Cloud Tier (HA)
Connect Cables and Power on
Length
2M
2M
2M
2M
5M
5M
5M
5M
2M
2M
2M
2M
Length
2M
2M
2M
2M
5M
5M
5M
5M
2M
port of the SSD shelf
2M
port of the SSD shelf
a
a
77