Connecting Multiple Ds60 Shelves To The Dd9500 /Dd9800 System; Dd9500 /Dd9800 - Dell Data Domain DD9500 Hardware Overview And Installation Manual

Hide thumbs Also See for Data Domain DD9500:
Table of Contents

Advertisement

Connect Cables and Power on
Connecting multiple DS60 shelves to the DD9500 /DD9800
system

DD9500 /DD9800

Data Domain DD9500 and DD9800 Systems 6.1 Hardware Overview and Installation Guide
70
The cabling diagrams in this section show the maximum configurations for the
DD9500 and DD9800 systems. Not all systems will have all the disk shelves shown in
the diagrams.
Some of the DS60 configurations described in the following sections also include
ES30 shelves for DD Cloud Tier metadata, or FS15 shelves for Metadata on flash.
Add shelf-to-shelf cables between shelves in a loop and to the controller as shown in
the diagrams.
1. The recommended cabling for DD9500/DD9800 systems with HA utilizes a
maximum of three loops.
2. There are no specific placement or cabling requirements for SSD shelves, or the
metadata shelves for DD Cloud Tier configurations. These shelves can be installed
and cabled the same way as standard ES30 shelves.
3. The SSD shelf counts towards the total number of shelves connected to the
system.
4. Data Domain recommends installing the SSD shelf in the V1.1 positon, but if that is
not possible, the shelf can be placed in a different location in the rack so long as
cables of sufficient length are available.
Note
V1.1 is recommended for better performance because this will the 1
data will be written. If the SSD shelf is connected to the last enclosure in a chain,
then each read/write request has to go through many hops, which introduces
latency issues when compared to when the SSD shelf is on the 1
5. Use the cable management assembly to support and organize all cables from the
DD9500/DD9800 system.
Select the appropriate configuration from the following list, and connect the disk
shelves to the Data Domain controller.
DD9500 /DD9800
on page 70
l
DD9500 /DD9800 with HA
l
DD9500 and DD9800 with DD Cloud Tier (Single node)
l
DD9500 and DD9800 with DD Cloud Tier (HA)
l
DD9500 and DD9800 with ERSO
l
For a base DD9500 /DD9800 system:
String
I/O - Port
(Loop)
1
I/O 6 - Port 0 A controller port 0 of shelf V1.1
1
I/O 2 - Port 1 B controller port 0 of the highest number shelf in V1
2
I/O 3 - Port 0 A controller port 0 of shelf V2.1
on page 73
on page 80
Shelf Port
st
hop where
st
shelf of a chain.
on page 75
on page 76
a
Length
2M
2M
2M

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Data domain dd9800

Table of Contents