Figure 6-18 Gmu 11 Overbraid Termination - Garmin G5 Installation Manual

Electronic flight instrument
Hide thumbs Also See for G5:
Table of Contents

Advertisement

Garmin G5 Electronic Flight Instrument Part 23 AML STC Installation Manual
NOTES:
[1] Install #10 grounding hardware in accordance with AC 43.13-1B, section 11-89. If
there is an existing hole located in an appropriate area it may be utilized for the
grounding hardware. If there is no existing hole usable for this purpose then drill and
de-burr a 0.191"-0.203" hole.
[2] MS25036-103 terminal lug (or equivalent).
[3] Terminal lug face or connecting hardware must not interfere with bend radius of rib
edge or stiffened holes. Stud hole must be located a minimum 1" from unstiffened
holes. Refer to MS20559 for lug dimensions.
[4] Refer to Section 4.6 for electrical bonding requirements.
[5] The exposed cable not having overbraid in the wing tip areas must be less than 2
inches.

Figure 6-18 GMU 11 Overbraid Termination

Page 175
190-01112-10
Rev. 9

Advertisement

Table of Contents
loading

Table of Contents