Grizzly G0827 Owner's Manual page 48

Horizontal/vertical mill w/dro
Table of Contents

Advertisement

5.
Fill headstock with oil to red mark on sight
glass (see Figure 73).
Figure 73. Red mark on sight glass indicates
headstock oil level is full.
Do not fill headstock with oil above red
mark. This could damage machine and
create an overflow of oil.
6.
Re-install oil fill plug.
7.
Discard used oil following federal, state,
and fluid manufacturer guidelines for proper
disposal.
-46-
Oil-Level
Sight Glass
Red Mark
Column
Oil Type ......Model T23963 or ISO 32 Equivalent
Oil Amount .......................................... 2.6 Quarts
Lubrication Frequency ........................... Annually
The column uses ISO 32 machine oil to lubricate
the gears, and is equipped with an oil-level sight
glass to gauge when the proper amount of oil is
in the column.
The amount of oil in the column must be regu-
larly monitored before each operation to ensure it
doesn't drop below sight glass visibility. Column
oil must be changed on an annual basis to ensure
proper lubricity of oil.
To change oil in column:
1.
DISCONNECT MACHINE FROM POWER!
2.
Loosen hex bolt shown in Figure 74 and
open rear column cover.
3.
Remove oil fill plug (see Figure 74).
Oil Drain
Plug
Figure 74. Column oil fill and drain locations.
4.
Hold drain pan under drain plug and remove
drain plug. Allow old oil to drain into drain
pan.
5.
Replace and tighten drain plug shown in
Figure 74.