Chapter 4: Testing Twisted Pair Through a PoE Device
The AC wire map test lets you test links connected through
midspan PoE (Power over Ethernet) devices. When you
enable this test, the tester uses AC signals instead of DC
signals to test the wire map between the main and remote
testers. The tester does not provide information on the PoE
device.
The DTX-ELT does not include the AC wire map
test.

Enabling the AC Wire Map Test

1
Turn the rotary switch to SETUP.
H
2
Press
to select Twisted Pair.
C
3
Press
to select tab 2.
D
4
Press
to highlight AC Wire Map; then press
H
.
D
5
Use
to highlight Enable; then press
Note
H
.
Always disable the AC Wire Map test when not
testing through a PoE device.
Autotest Through a PoE Device
1
Enable the AC Wire Map test.
2
Connect to the cabling as shown in Figure 4-1 for a
permanent link or Figure 4-2 for a channel
3
Verify that the PoE device is turned off.
4
Run an Autotest as described on page 3-6.
When the AC Wire Map test is enabled:
• The Autotest may run slower.
• Some tests, such as resistance, are not run.
• The Autotest does not stop if a wire map fault is
detected.
• The AC Wire Map test requires a smart remote.
Note
Notes
4-1