Fluke DTX-1800 Technical Reference Handbook page 135

Dtx series cable analyzer
Hide thumbs Also See for DTX-1800:
Table of Contents

Advertisement

Setting
Select the appropriate test limit for the job.
SETUP > Coaxial
> Test Limit
Select a cable type appropriate for the type you will test.
SETUP > Coaxial
> Cable Type
Nominal velocity of propagation, which is used with the measured propagation delay to determine cable
SETUP > Coaxial
length. The default value defined by the selected cable type represents the typical NVP for that cable
> NVP
type. You may enter a different value if necessary. To determine the actual value, change the NVP until
the measured length matches the known length of a cable. Use a cable at least 30 m (100 ft) long. See
page 12-10.
Increasing the NVP increases measured length.
Table 5-1. Coaxial Cable Test Settings
Description
Certifying Coaxial Cabling
Coaxial Test Settings
-continued-