Fluke DTX-1800 Technical Reference Handbook page 278

Dtx series cable analyzer
Hide thumbs Also See for DTX-1800:
Table of Contents

Advertisement

DTX Series CableAnalyzer
Technical Reference Handbook
Power meter measurement is too low
Fiber endface is dirty or damaged.
Test reference cord not connected to tester's INPUT port, or a connection is loose.
Wavelength selected on tester doesn't match source wavelength.
Source set to modulated output.
Test reference cord or adapter is the wrong type (SM or MM) or test reference cord has the wrong core size.
Cabling is cracked or broken.
Power meter measurement is too high
Tester is connected to an active CATV fiber.
No FindFiber connection in Smart Remote or Loopback mode when fiber paths are complete
The remote tester is in Far End Source mode, indicated by a solid red or green LED below the OUTPUT port. To exit Far
End Source mode, press the button on the module until the LED blinks green.