2) Background fogging
Defective area
Density reproduction
Printer section
Parameter adjustment
value
Scanner
Developer material/Toner/
Photoconductive drum
e-STUDIO520/523/600/603/720/723/850/853
TROUBLESHOOTING
Fig. 5-2
Step
Check items
1
Check the reproduction of the image
density.
2
Check test print image (04-113).
3
Check the image processing param-
eter.
4
Are the original glass (especially
shading position),mirrors and lens
dirty?
5
Using the specified developer mate-
rial, toner and photoconductive
drum?
6
Have the developer material and the
photoconductive drum reached their
PM life?
7
Is the storage environment of the
toner cartridge 35°C or less without
dew?
5 - 128
Prescription
Adjust the density.
Go to step 4 if there is any problem
on image.
Check the range correction setting
and the adjustment value of the
background peak for range correc-
tion. ( ch. 3.3.4, ch. 3.3.5)
If they need to be adjusted, check the
print image in the above circle mark
to adjust the adjustment value of the
background peak for range correc-
tion.
Clean them.
Use the specified developer material,
toner and photoconductive drum.
Replace the developer material and
photoconductive drum.
Use the toner cartridge stored in the
environment within specification.
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved