Notes:
1. Wipe the tip of the finger lightly with a dry cloth trying not to deform it.
Do not leave the lint on the tip.
2. Apply patting power to the tip of the fingers and drum surface after replacing or cleaning them.
* 11.
Cleaner auger drive section
Apply white grease to the cleaner auger drive section (shown by arrow).
* 12.
Developer material
After replacing the developer material, be sure to perform the auto-toner adjustment and
then enforced erforming of image quality control.
(
P.3-3 "3.2 Image Dimensional Adjustment")
When removing the developer material from the developer unit with a vacuum cleaner or
air blower, be sure to ground the bracket of the developer unit to prevent the auto toner
sensor from being damaged by static electricity.
* 13.
Oil seal
Mixer shaft .......................................................4 pcs.
Paddle shaft ....................................................2 pcs.
Upper developer sleeve (rear side) .................1 pc.
Lower developer sleeve (rear side) .................1 pc.
Transport sleeve (front side) ............................1 pc.
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-18
Connected to earth
Fig. 4-19
e-STUDIO520/523/600/603/720/723/850/853
4 - 25