Note:
Note:
When cleaning the auger section with a vac-
uum cleaner, be sure to ground the motor
bracket to prevent the motor from being
damaged by static electricity.
* 15.
Transfer belt power supply roller
Fully clean up the toner and such adhered to the roller with alcohol since an image failure
may occur if there remains any blot on the roller.
* 16.
Transfer belt cleaning bush/Flicker periphery
When replacing the transfer belt cleaning brush, clean the toner pooling under the brush
(around the flicker).
* 17.
Upper separation finger
The paper jam may be caused if the tip of the finger is damaged or deformed. If there is
any problem with it, replace the finger with a new one regardless of the number of copies
which have been made.
Do not damage the tip of the finger during the cleaning. The finger may be damaged if the
toner adhering to the tip of it is scraped off forcibly. Replace the finger if the toner is stick-
ing to it heavily.
e-STUDIO520/523/600/603/720/723/850/853
PREVENTIVE MAINTENANCE (PM)
Blot
Fig. 4-26
Flicker
periphery
Fig. 4-27
4 - 28
05/06
Connected to earth
Fig. 4-25