Toshiba e-STUDIO520 Service Handbook page 250

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [COPY] to make a copy at the mode of A3 (LD), 100% and the 2nd/4th drawer.
(4)
Measure the distance C from 10 mm to 210 mm of the copied image of the ruler.
(5)
Check if the distance C is within the range of 200±0.5 mm.
(6)
If not, use the following procedure to change values and repeat steps (3) to (5) above.
(Adjustment Mode)
(Key in a value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
("100% A" is displayed.)
* The smaller the adjustment value is, the lower the reproduction ratio becomes (0.46 mm/
step).
50
e-STUDIO520/523/600/603/720/723/850/853
ADJUSTMENT
(Key in the code [340])
Copied image of the ruler
100
150
200
C
Fig. 3-18
(Adjustment Mode)
[START]
250
300
Feeding direction
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
3 - 18
350
400